Aussie Owned & Operated

Pre-Made Kits to suit every application

Our Service Difference

Sale!

Victron BatteryProtect 12/24V-65A

$55.93 (inc. GST)

The Victron BatteryProtect 12/24V-65A is a battery protection device designed to prevent damage to your battery by disconnecting the load when the battery voltage drops below a certain level. This is important because discharging a battery beyond its safe limit can significantly reduce its lifespan and performance.

SKU: BPR000065400 Categories: ,

Victron BatteryProtect:

The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

Features: 

12/24V auto ranging- The BatteryProtect automatically detects system voltage

Programming made easy- The BatteryProtect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen.

A special setting for Li-ion batteries- In this mode the BatteryProtect can be controlled by the VE.Bus BMS.

Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.

Ultra low current consumption- This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.

Over voltage protection- To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.

Ignition proof- No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output- The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.

Additional information

BatteryProtect

BP-65

Maximum continuous load current

65A

Peak current (during 30 seconds)

250A

Operating voltage range

6 –35V

Current consumption

When on: 1,5 mA When off or low voltage shutdown : 0,6 mA

Alarm output delay

12 seconds

Maximum load on alarm output

50 mA (short circuit proof)

Load disconnect delay

90 seconds (immediate if triggered by the VE.Bus BMS)

Load reconnect delay

30 seconds

Default thresholds

Disengage: 10,5V or 21V Engage: 12V or 24V

Operating temperature range

Full load: -40°C to +40°C (up to 60% of nominal load at 50°C)

Connection

M6

Weight

0,2 kg 0.5 lbs

Dimensions (hxwxd)

40 x 48 x 106 mm

1.6 x 1.9 x 4.2 inch

Download

Datasheet-Battery-Protect-65-A–100-A–220-A-ENVictron 12/24V 65A BatteryProtect spec Sheet-

Manual-Battery-Protect-12V-24V-65-A-100-A–220-A-EN-NL-FR-SE-DE-PT-ES-ITVictron 12/24V 65A BatteryProtect manual-